Accidents, Safety Analysis & Severe Accidents · C-SA-020

Critical Safety Functions (CSF) — Monitored Variables, Status Trees, Priorities and the SPDS for the Six Functions

Keep the functions and the barriers hold, whatever the cause: six status trees read from measured variables, handled by colour and then priority.

Definition

Critical safety functions (CSFs) are the set of functions that, if maintained, keep the fuel, RCPB and containment barriers intact regardless of what caused the accident. Operators judge the status of each function from measured variables and restore the threatened functions first.

The Westinghouse (W) Emergency Response Guidelines (ERGs) define six: subcriticality, core cooling, heat sink, primary system integrity, containment and inventory. This note covers the monitored variables, the decision values and the tree logic for each function.

Principle and mechanism

Origin — "protect the functions and you need not know the cause"

Corcoran and co-workers (1981, Nuclear Technology, vol. 55) grouped the operator actions that prevent core melt and reduce releases into "safety functions". They proposed ten functions, covering reactivity; RCS inventory and pressure; core and RCS heat removal; containment isolation, temperature and pressure, and combustible gas; maintenance of vital auxiliaries; and control of indirect releases. After TMI-2, NUREG-0737 I.C.1 and NUREG-0899 (1982) required symptom-based EOPs. The reactor owners' groups built the concept into their procedures: W with six CSFs and status trees (CSFSTs), the CE type with a function-by-function safety function status check (SFSC).

The six CSFs — barriers protected and variables monitored

CSF (priority)Barrier protectedMain monitored variablesRed/orange exampleRecovery procedure gist
① Subcriticality SFuel and claddingPower-range power, intermediate- and source-range SURPower ≥ 5 % red; positive intermediate-range SUR orangeFR-S.1 manual trip, emergency boration
② Core cooling CFuel and claddingCET, subcooling, RVLISCET > 1,200 °F redFR-C.1 maximize SI, depressurize SGs, start RCPs
③ Heat sink HRCPB (indirectly the core)SG narrow-range level, total feedwater flow, SG pressureRed when both level and feed are insufficientFR-H.1 restore feedwater; if that fails, feed and bleed
④ Primary system integrity PReactor vesselCold-leg cooldown rate and temperature, RCS pressure (P-T)Cooldown > 100 °F in 60 min + beyond Limit A redFR-P.1 stop cooldown, depressurize, hold temperature
⑤ Containment ZContainmentContainment pressure, sump level, radiationAbove design pressure redFR-Z.1 confirm sprays, fan coolers, isolation
⑥ Inventory IRCS inventory (indicator)Pressurizer level, RVLIS upper rangeYellow onlyFR-I.1–3 adjust charging and letdown, vent voids

The decision values are from a W four-loop plant (the Salem Unit 2 CSFST basis document) and differ from plant to plant. The heat sink tree has no orange path. The inventory tree's unsatisfied paths are yellow only, because inventory is an early indicator for the other functions. The Salem procedure writes orange as PURPLE; procedure numbers here follow the ERG notation (FR-x.y).

Cutaway of an upper reactor vessel marking a core exit thermocouple point and the RVLIS differential pressure tap, beside the Westinghouse core cooling status tree: five or more CETs above 1,200 °F gives red FR-C.1; RCS subcooling above 0 °F gives green; with RCPs running, RVLIS dynamic range above 44, 30, 20 or 13 percent for 4, 3, 2 or 1 pumps gives yellow FR-C.3, otherwise orange FR-C.2; with RCPs off, CETs above 700 °F combined with RVLIS full range above or below 39 percent give red, orange or yellow
The core cooling status tree (Westinghouse CSF F-0.2). Values are from the Salem Unit 2 (W four-loop) example and are plant-specific; 39 % is a collapsed level 3.5 ft above the bottom of the core plus uncertainty, and 44 % corresponds to 50 % average void.

Reading a status tree — the core cooling example

The tree is a binary decision path read from the top down with yes/no answers.

  1. Five or more CETs > 1,200 °F (649 °C): most of the coolant is gone and the steam is superheated. Red; go to FR-C.1. This value already includes the instrument uncertainty (about 200 °F).
  2. Subcooling > 0: if satisfied, green.
  3. RCPs running: if the RVLIS dynamic range is below the value for 50 % void fraction (44 % with four pumps), orange FR-C.2; if above, yellow FR-C.3.
  4. RCPs off: combine CET above 700 °F (371 °C) with RVLIS full range 39 %. The 39 % is a collapsed level of 3.5 ft above the bottom of the core plus uncertainty. If both are bad, red; if one is bad, orange; if both are fine, yellow.

Hot-leg temperature is not used for the decision, because in some core-uncovery scenarios it responds later than the CETs. "Five or more" is that plant's condition for screening out failed thermocouples.

Colours and priority

ColourMeaningOperator action
RedExtreme challengeStop the procedure in progress and go to the FR immediately
OrangeSevere challengeEnter when there is no red
YellowNot satisfiedOperator judgement when there is no red or orange
GreenSatisfiedKeep monitoring

The priority S → C → H → P → Z → I is the order of handling when the same colour appears in several trees at once. A red in any tree comes before any orange. After an FR's actions are complete and the operator returns to the original procedure, the same colour may remain (for example, the containment tree); whether to repeat it then follows the return instruction of that FR.

What it means in a plant

When and how often to monitor

  • Start: monitoring begins when E-0 (reactor trip or safety injection) directs it, or on transfer from E-0 to another EOP. Right after the trip, E-0's immediate actions come first. If E-0 step 1 fails to confirm reactor trip (ATWS), however, the operator goes straight to FR-S.1. Some plants implement tree monitoring in parallel with the E-0 diagnostic steps (NRC public plant documents), so the start time follows the unit's procedures.
  • Method: all six trees are checked and logged together at first, and then monitored continuously. In the Salem example, once all are green or yellow and stable, the interval can be relaxed to 15 minutes on the CRS's instruction.
  • End: CSFST monitoring ends when the operator leaves the EOP network. During ECA-0.0 (loss of all AC power), the trees are only monitored and the operator does not transfer to FRs.
Timeline from reactor trip and safety injection through E-0 immediate actions, start of monitoring when E-0 directs it or on transfer to another EOP, checking and logging all six trees, continuous monitoring relaxed up to 15 minutes when stable, and the end of CSFST monitoring on leaving the EOP network; a matrix of FR procedures by colour for the subcriticality, core cooling, heat sink, integrity, containment and inventory trees, with no orange path for heat sink and yellow only for inventory; and actions by colour
When CSF monitoring starts and ends, and the order of handling: colour first, then tree priority S → C → H → P → Z → I. FR mapping and the 15-minute interval are from the Salem Unit 2 example.

CE-type plants — means-based judgement

The OPR1000 and APR1400 designs follow the CE structure. What is judged is the success of each function's success path (the equipment in use). For example, the criteria for the core and RCS heat removal path HR-1 (SG cooling without SIS operation) check SG level or feedwater flow, the RCS ΔT, CET-based subcooling and the upper head level against plant-specific values.

If not satisfied, the operator moves to the next path on the resource tree (cooling with SIS operation → once-through cooling). W emphasizes diagnosing the function status to select the FR procedure; the CE type emphasizes judging which means is keeping the function.

SPDS — the CSFs on one screen

NUREG-0696 (1981) defined the SPDS in the functional criteria for emergency response facilities. NUREG-0737 Supplement 1 (1982) set the minimum information as five functions: reactivity control, core cooling and primary heat removal, RCS integrity, radioactivity control and containment conditions. Because implementation was weak, the NRC followed up with GL 89-06 and NUREG-1342. The SPDS is an auxiliary display; decisions are confirmed on safety-grade indicators (at Salem, the CET display is the only exception). In the APR1400, SPADES+ provides CSF displays and alarms integrated into the main control room design.

Boundary with the SAMG

The depressurization and RCP start of FR-C.1 may not work. If the CET then keeps rising above 1,200 °F, the operator moves to the SAMG. A red core cooling tree is not by itself SAMG entry. The detailed SAMG entry logic follows each unit's guidelines. The diagnostic flow chart and severe challenge status tree of the WOG SAMG carry the CSF tree concept beyond core damage.

Regulatory and design criteria

For example, the US NRC and IAEA references:

BasisKey point
NUREG-0737 I.C.1 (1980) / NUREG-0899 (August 1982)Improvement of symptom-based EOPs and writing guidelines
NUREG-0737 Supp.1 (GL 82-33, December 1982)Five functions as the minimum SPDS information
NUREG-0696 (February 1981)Functional criteria for emergency response facilities and the SPDS
10 CFR 50.34(f)(2)(iv), NUREG-0700 Section 5SPDS requirement and design guidance
IAEA SSR-2/1 Rev.1, Requirement 4Three fundamental safety functions

Easily confused pairs

W CSF (CSFST)CE safety functions (SFSC)SPDS five functionsIAEA fundamental safety functions
Number69 (CE-type SPTA)53
What is judgedVariable statusSuccess of the success pathDisplay scopeDesign requirement
GradesRed, orange, yellow, greenSatisfied, challenged, jeopardized——
OutputDesignates an FR procedureRecovery procedure, next pathAid to operator judgementDesign demonstration

Key points at a glance

  1. Definition: functions that, if maintained, keep the barriers intact regardless of cause; the decision basis of symptom-based EOPs.
  2. Origin: Corcoran et al. (1981), ten functions → after TMI, NUREG-0737 and NUREG-0899.
  3. Six (by priority): subcriticality S → core cooling C → heat sink H → integrity P → containment Z → inventory I.
  4. Monitored variables: SUR and power / CET, subcooling, RVLIS / SG level and feedwater / cooldown rate and P-T / containment pressure, sump level, radiation / pressurizer level.
  5. Colours: red, FR at once; orange, when no red; yellow, judgement; green, satisfied.
  6. Core cooling example: CET > 1,200 °F red; combination of 700 °F and RVLIS 39 % (W plant example).
  7. Monitoring: continuous from E-0's instruction or transfer; interval relaxed when stable; monitor only during ECA-0.0.
  8. CE-type plants (e.g. OPR1000, APR1400): nine functions; SFSC satisfied, challenged, jeopardized; success-path judgement.
  9. SPDS: NUREG-0696, Supp.1 five functions, APR1400 SPADES+.
  10. SAMG: FR-C.1 fails + CET rising → SAMG.
  11. Links by barrier: S, C and H protect the fuel and cladding; H, P and I protect the RCPB; Z protects containment. Losing the heat sink (H) threatens core cooling (C) and then integrity (P) in turn.
Sketch of the core cooling status tree: five or more CETs above 1,200 °F gives red FR-C.1, RCS subcooling above 0 °F gives green, and with RCPs off, CETs above 700 °F and RVLIS full range above 39 percent lead to red FR-C.1, orange FR-C.2 or yellow FR-C.3, with a note on the RCPs-running dynamic-range check of 44 percent
Core cooling status tree (Salem Unit 2 example, RCPs-off path simplified).