Xenon Dead Time — The Window After Shutdown When Xenon Exceeds the Available Excess Reactivity

Restart is blocked while the xenon reactivity loss L(t) exceeds the available margin M; the window is the interval between the two roots of L(t) = M.

Definition

The xenon dead time is the period after reactor shutdown during which 135Xe builds up until its reactivity loss exceeds the available excess reactivity for restart (all rods withdrawn, boron diluted to the minimum), so that criticality cannot be reached within the assumed operating conditions. It is also called the xenon-precluded startup period.

This entry covers only the point where the two concepts meet: from when to when is restart blocked, and what sets its length?

Principle and mechanism

Why it happens: three conditions

  1. The burnout path disappears: during operation xenon is removed mainly by neutron absorption (σaφX). At shutdown φ = 0, and this path vanishes.
  2. 135I decays faster: 135I (T½ 6.7 h) decays faster than 135Xe (T½ 9.2 h), so for a while after shutdown production (λII) exceeds decay (λXeX). Xenon therefore peaks at around 10 hours.
  3. The available margin is finite: the reactivity available for restart, M, decreases with burnup.

The test is simple. With the xenon reactivity loss L(t) = −ρXe(t), the interval where L(t) > M is the dead time, and its start t₁ and end t₂ are the two roots of L(t) = M. M is the xenon-free excess reactivity at restart conditions (hot zero power) with all rods out and boron at its minimum, with burnup and other poisons held fixed. The power-defect recovery is already contained in this M, so it is not added separately.

After shutdown, xenon follows the analytic solution

X(t) = X₀e−λXe·t + λII₀/(λI − λXe)·(e−λXe·t − e−λI·t)

where I₀ and X₀ are the equilibrium values before shutdown.

The window opens and closes with the available margin

Using a textbook one-group model (Lamarsh constants), a shutdown from equilibrium operation at φ = 5×10¹³ n/cm²·s was calculated. The equilibrium loss is 2,365 pcm, and the post-shutdown peak is 6,296 pcm at 9.5 hours.

Available margin MStart t₁End t₂Length
3,000 pcm0.6 h29.5 h28.9 h
4,000 pcm1.8 h24.0 h22.2 h
5,000 pcm3.4 h19.0 h15.6 h
6,000 pcm6.3 h13.4 h7.1 h
≥ peak 6,296 pcm——None
Map of the xenon dead time: time after shutdown from 0 to 48 h against available excess reactivity M from 2,000 to 7,000 pcm; the shaded window for φ = 5×10¹³ narrows from 0.6–29.5 h at M = 3,000 to a point at the 6,296 pcm peak at 9.5 h, with the M = 4,000 case marked as 1.8–24.0 h (22.2 h); dashed boundaries for φ = 1×10¹⁴ (wider) and φ = 2.5×10¹³ (peak 3,612 pcm at 8.1 h); and a table of start, end and length by M
The dead-time window versus the available excess reactivity M, for shutdown after equilibrium operation (textbook one-group model with Lamarsh constants; real PWR values depend on spectrum-averaged cross sections and core design). The photograph is illustrative.

Three things can be read from it.

  • The larger M, the later the window starts and the earlier it ends. When M reaches the peak, the window disappears.
  • If M is at or below the equilibrium loss, restart is blocked from the moment of shutdown. In a core that was able to operate normally, M is usually larger than the equilibrium value because of the power-defect recovery.
  • Restart is possible before t₁. That is why, if the cause of a trip is cleared quickly, a prompt restart avoids the xenon peak.

The higher the flux before shutdown, the longer it lasts

Equilibrium xenon saturates once φ exceeds φX (≈ 7.9×10¹²), but the post-shutdown peak is proportional to the 135I inventory at the moment of shutdown, so it grows almost in proportion to φ. The peak-to-equilibrium ratio is 1.22 at φ = 1×10¹³, 2.66 at 5×10¹³ and 4.55 at 1×10¹⁴. Below the threshold flux at which the peak equals M (M 3,000 → 1.95×10¹³, 4,000 → 2.85×10¹³, 5,000 → 3.78×10¹³) there is no dead time; above it, the higher φ, the longer the dead time.

Two log-axis charts against pre-shutdown thermal flux from 10¹³ to 3×10¹⁴ n/cm²·s: left, equilibrium xenon saturating near 2,500 pcm while the post-shutdown peak rises steeply, crossing M = 3,000, 4,000 and 5,000 pcm at thresholds of 1.95, 2.85 and 3.78×10¹³; right, dead-time length rising from zero at each threshold, reaching 28.9, 22.2 and 15.6 h at φ = 5×10¹³
Peak and equilibrium xenon versus pre-shutdown flux, and the resulting dead-time length for three values of M (analytic iodine–xenon solution, textbook one-group model, not real core values).

What governs these results is σaφ/λXe = φ/φX. In a real hot PWR the spectrum-averaged effective absorption cross section is smaller than the 2,200 m/s value, so comparisons between reactor types must be made on the same σaφ/λXe basis.

For a planned shutdown, reducing power beforehand also helps. Shutting down after reaching equilibrium at 50 % power (φ = 2.5×10¹³) gives a peak of 3,612 pcm, about 57 % of the 6,296 pcm when shutting down from 100 %. Right after a power reduction, however, xenon temporarily increases, so the benefit only appears after some tens of hours.

What it means in a plant

PWR: usually margin at BOC, a constraint at EOC

  • Beginning of cycle (BOC): the hot full-power critical boron concentration is high (about 1,000–1,500 ppm in a reload core, as an example), so the reactivity obtainable by dilution is generally larger than the increase to the xenon peak. Restart is therefore usually possible even after a shutdown.
  • End of cycle (EOC): the full-power critical boron falls to a few tens of ppm or less, leaving almost no dilution capacity. The available margin at restart conditions is roughly "equilibrium xenon + power-defect recovery (about 2,100 pcm at EOL, as an educational example) + remaining boron". If the increase to the xenon peak exceeds this, a dead time appears, and it grows longer toward the end of the cycle.
  • Inefficiency of dilution at low boron: feed-and-bleed dilution proceeds as C(t) = C₀e−Qt/V, so the lower the concentration, the slower the ppm reduction. For this reason a deborating ion exchanger may be used at end of cycle.

CANDU: a window of tens of minutes

CANDU heavy-water reactors keep excess reactivity small through on-power refuelling. The time during which xenon can be overridden by withdrawing the adjuster rods is reported to be about 30–40 minutes after shutdown. If this is missed, the reactor is poisoned out and must wait more than a day for the xenon to decay.

Operating responses

  1. Prompt restart: if the cause is cleared at once, reach criticality before t₁.
  2. Planned shutdown after power reduction: lower the pre-shutdown power to reduce the peak.
  3. Wait for decay: restart after t₂, recalculating the estimated critical position (ECP) with the xenon for the elapsed time.
  4. Monitoring after restart: if xenon is still decreasing, positive reactivity keeps coming in. Raising power increases xenon burnout, requiring boration or rod insertion, and an asymmetric axial xenon distribution calls for monitoring of xenon oscillations.

The xenon dead time is not a safety problem but an operational availability (capacity factor) problem. While xenon is high, the core is more deeply subcritical. Conversely, restarting while xenon is decaying adds reactivity continuously, so shutdown margin and insertion limits must be managed carefully.

Regulatory and design criteria

The following US references are examples.

BasisKey point
10 CFR 50 App. A GDC 26Two independent reactivity control systems of different design principles, one able to control the rate of reactivity change from planned normal power changes (including xenon burnout)
NUREG-0800 SRP 4.3Reactivity control capability, evaluation of xenon effects
NUREG-1431 STS LCO 3.1.1, 3.1.6Shutdown margin, control bank insertion limits. SR 3.1.6.1 verifies, before reaching criticality, that the estimated critical position is within the insertion limits

No provision regulates the xenon dead time directly, because it is an operational availability issue; the safety side is managed through shutdown margin and insertion limits.

Easily confused pairs

Xenon dead timeXenon peakShutdown marginCounter dead time
DefinitionInterval where L(t) > MMaximum of L(t) after shutdownDepth of subcriticality when shut downTime τ in which pulses cannot be resolved
Unithpcm (at about 10 h)pcm, %Δk/kμs
Set byPre-shutdown φ, MPre-shutdown φControl worth, stuck-rod assumptionDetector and electronics
NatureOperational availabilityPhysical phenomenonSafety limitInstrument correction

The time of the peak lies in the middle of the window, not at its start; the start is when xenon first crosses the margin line. Counter dead time is an entirely different concept, used in the true-count-rate correction n = m/(1 − mτ).

Key points at a glance

  1. Definition: interval after shutdown where the Xe-135 reactivity loss > available excess reactivity (all rods out, minimum boron) → criticality impossible.
  2. Cause ①: shutdown makes φ = 0 → the xenon burnout path is removed.
  3. Cause ②: 135I (6.7 h) decays faster than 135Xe (9.2 h) → peak at about 10 h after shutdown.
  4. Cause ③: the available margin is finite and decreases with burnup.
  5. Test: the two roots t₁, t₂ of L(t) = M; none if the peak < M.
  6. Influencing factors: higher pre-shutdown φ → higher peak, longer window; larger M → shorter window.
  7. PWR: at BOC the boron dilution capacity is large and restart is usually possible; the dead time appears and lengthens at EOC with low boron.
  8. CANDU: poison-out if not restarted within about 30–40 minutes after shutdown.
  9. Responses: prompt restart before t₁, shutdown after power reduction, wait for decay and recalculate the ECP, monitor xenon oscillations after restart.
  10. Distinctions: an availability problem, not a safety limit; different from counter dead time.
Sketch of xenon reactivity loss versus time: flat before shutdown, rising after shutdown to a peak at about 10 h and then decaying; a high dashed line for the BOC available margin (restart possible) and a lower dotted line for the EOC available margin, which the curve crosses at t₁ and t₂, with the interval between marked as the xenon dead time
Sketch: post-shutdown xenon curve with illustrative BOC and EOC margins; the test is the peak versus the available margin.